Solar Energy Manager for ESP32 (SEM.32)

GitHub Repo stars GitHub watchers GitHub forks Release

SEM.32 (Solar Energy Manager 32) based on ESP32 controller, Soyosource Inverter, Huawei r4850g2 power supply, JK-BMS and 48V battery. It helps You to maximize the usage of self generated solar power.

Main features:

  • control of inverter to minimize power usage out of the grid (over RS485)
  • control of charger to maximize own usage of solar power (over CAN-bus)
  • adjustable power thresholds
  • optional manual control of charging power
  • optional dynamic load calculation to reduce wear of battery due to low chage status
  • charge current limitation
  • access to JK-BMS data (over RS485)
  • new web GUI
  • wifi configuration portal
  • MQTT client
  • scalable code for new features
  • CAN dbc file for the charger
  • runs ESP32 boards with RS485+CAN shield
  • runs on ESP32 and on the BSC-Hardware

Web GUI

Summary page

Info page

Settings page

Hardware components:

  • Inverter:

    • Type: GNT 1200LIM 48
    • MAX: Const. Power: 800W (1200W solar operation)
  • Charger:

    • Type: Huawei R4850G2
  • BMS:

    • Type: JK-BD6A20S8P
    • Software V.: V10.XY
  • Battery cells:

    • Type: EVE LF90 (3,2V 90AH, Nominal)
    • Datasheet No.: LF90-73103
    • Cut off Voltage: 3.65V/2.5V
    • Std. charge/Discharge: 1.0C
  • Power Meter:

    • Type: Tasmota based smart meter from Hitchi
  • Controller:

  • CAN interface:

    • Driver IC: SN65HVD230
  • RS485 Serial interface:

    • Driver IC: Max485 CSA (2 pcs. for BMS and Inverter)
  • 0.96 inch OLED IIC 128x64 Display:

    • Driver: SSD1306
    • I2C Addr.: 0x3C
  • Temperature Sensors:

    • 1-Wire
    • Type: DS18B20 waterproof

External connectors:

USB upper:

Pin 2 (RXD/D-) Output A Max 485 USB Driver for inverter, Inverter Input A+

Pin 3 (TXD/D+) Output B Max 485 USB Driver for inverter, Inverter Input B-

USB Lower:

Pin 2 (RXD/D-) CAN L

Pin 3 (TXD/D+) CAN H

RJ45:

Pin 1 (Pair 3) Output A Max 485 USB Driver for BMS, BMS Input A+

Pin 2 (Pair 3) Output B Max 485 USB Driver for BMS, BMS Input B-

6 pin connector:

Pin1 GPIO26 Temp Sensor

Pin2 Ground

Pin3 +3V3

Pin4 NC

Pin5 NC

Pin6 NC

Pinning Controller

GPIO Function Application Driver
GPIO00 Boot Push Burron 1
GPIO01
GPIO02
GPIO03
GPIO04 CAN RX Charger SN65HVD230
GPIO05 CAN TX Charger SN65HVD230
GPIO06
GPIO07
GPIO08
GPIO09
GPIO10
GPIO11
GPIO12 LED Blue, Charging
GPIO13 LED Green, Discharging
GPIO14 LED Yellow, Standby
GPIO15 LED Red, ERROR
GPIO16 U2RXD Inverter Max485 CSA
GPIO17 U2TxD Inverter Max485 CSA
GPIO18 RS485_EN Chip enable, Inverter Max485 CSA
GPIO19
GPIO21 I2C SDA1 Display SSD1306 Address: 0x3C
GPIO22 I2C SLC1 Display SSD1306 Address: 0x3C
GPIO23
GPIO25
GPIO26 DAT Temp. Sensors DS18B20; inc. 4K7 pull up
GPIO27
GPIO32 RS485 RxD BMS Max485 CSA
GPIO33 RS485 TxD BMS Max485 CSA
GPIO34 RS485_EN BMS Max485 CSA
GPIO35 Dig_input Push Button 3
GPIO36 Dig_input Push Button 2
GPIO39 LED auxiliary

Information:

Power Equation for the whole house: $\ ActGridPower + ActBatPower + SolProd = Used Power$

JSON help: https://arduinojson.org/v6/assistant/#/step1

ESP32 infos: https://www.upesy.com/blogs/tutorials/how-to-connect-wifi-acces-point-with-esp32

BSC (Battery Safety Controller) homepage: https://github.com/shining-man/bsc_fw

JK-BMS Protocol: jblance/mpp-solar#112 (comment)

JK-BMS collection of NEEY: https://github.com/NEEY-electronic/JK/tree/JK-BMS

Known issues:

Solution for Littlefs error: pio pkg update -g -p espressif32