Notifications
You must be signed in to change notification settings - Fork 43
Iiyama
VCP Version: 2.1
Controller manufacturer: unknown (feature code xC8 unsupported)
Firmware version: unknown (feature code xC9 unsupported)
Manufacture year: 2013
Color temperature increment (feature x0B) and request (feature x0C) result in a color temperature of 26,100 degress Kelvin
Does not include command x02 (VCP Response) or xE3 (Capabilities Reply) in its capabilities string, even though these are supported.
Responds to several VCP feature not listed in capabilities.
VCP Version: 2.2 (reported by capabilities string), 2.1 (reported by feature xdf)
Controller Manufacturer: RealTek (controller number mh=x00, ml=x27, sh=x85)
Firmware version: 0.0
Manufacture year: 2020
Color temperature increment (feature X0B): 100 degrees Kelvin
Color temperature request (feature X0C): results in a nonsensical color temperature of 1300 degrees Kelvin
Requires that a Save Current Settings packet (command scs) be sent immediately after a Set VCP Feature packet (command setvcp) to actually set the value.