Add test for epma image Replace tmpdir with pytest's tmp_path
Codecov ReportPatch coverage:
Additional details and impacted files@@ Coverage Diff @@
## main #118 +/- ##
==========================================
+ Coverage 85.26% 85.27% +0.01%
==========================================
Files 73 73
Lines 9030 9051 +21
Branches 2045 2048 +3
==========================================
+ Hits 7699 7718 +19
- Misses 871 872 +1
- Partials 460 461 +1
☔ View full report in Codecov by Sentry. |
@nem1234 , what do you mean signal type EPMA? "EPMA" is type of method and/ or specific analytical instrument (Electron probe micro-analysis or analyzer, depending from context). The signal should be either EDS or WDS... if it would have energy or wavelength dimension, but actually this is just "raw counts". If it would be background corrected (with subtracted background) it could be called "net counts" (but I highly doubt Jeol probe software is even able to do that). If it is from Jeol EPMA it is probably collected raw xray counts at fixed WDS position set at known X-ray line energy and scaled down to fit 8 bits. Taking into consideration that it even should not be called a "raw counts" - it is just simple image with no exposed relationship to counts. However, is Rosettasciio the right place for static single 8 bit, fixed resolution maps? If this is implemented, then maybe I should add subset of reader for Cameca EPMA mapping files and WDS spectral scans too (which compared to this poor file is overwhelmingly metadata-wise feature complete)? I would doubt about that, but after seeing usage cases with PCA and other methods on EDS hypermaps I start to wonder if similar methods would not be applicable on stacked WDS raw (or better, net count intensity) maps. Or ultimately stacked k-ratio maps... To fool-proof this implementation, I would ask the author to produce more such files with different resolutions and different maximum count rates - it could reveal if there is indeed no additional flags in header (it does not sound right that there is only fixed single 256x256 pixel ratio), maybe there are enumerates for resolution and bit depth, where lowest resolution of 256x256 happens to be binary 00, and 8 bit int also is a binary 00 in corresponding enum. At this point in my opinion there is a bit too much unknowns with this single file for implementation. It is not kind of bug fix, it is a whole new format being introduced. |
Thank you. In my recognization, PR should be small, step-by-step commit to main tree. |
@nem1234 you can always open a PR and set the PR as a draft! That helps to signal that you are still working on some things or that you might need help. Getting feedback is a part of the process and it is nice to know what people are doing so things aren't duplicated! My general rule of thumb is try and get something working to the point where I can at least provide an example of an implementation and then submit a PR. If you want you can reopen this PR and mark it as a draft then maybe we can think about generalization of the file format if we can find more methods. @sem-geologist I'd say that more of these processed datasets do have a place in rosettasciio. If the idea is to reduce the dependency on 3rd party applications I think that's pretty well in line but we could open an issue or discussion. |
wait, is it not possible to get some more data from the author of this file? I think this could be good to have. As I said, during EMAS workshop I had seen really relevant presentations utilizing HyperSpy behind. Multi-WDS instruments (basically one of optional characteristics of EPMA instrument) can produce more concentrated view on X-ray generated in the sample. As I said I see potential of all these advanced methods built inside hyperspy, where instead of EDS spectral image, stacked raw or net count WDS cube could be used. Blind source separation, PCA and other methods should work same and maybe even better than on EDS, as this would be much less noisy measurements and much more sensitive to low concentrations. While HyperSpy lacks on X-ray quantification, I got convinced that not always there is a need or even is impossible to use standard based quantification. So please don't close this PR, it would motivate me to bring in Cameca formats here too. |
Draft
This is not suitable for merging into main stream
more sample data is needed
Description of the change
Progress of the PR
upcoming_changes
folder (seeupcoming_changes/README.rst
),readthedocs
doc build of this PR (link in github checks)Minimal example of the bug fix or the new feature
This is just a minimum EPMA map support for discussion.
I don't know if new signal_type should be defined or not.