Notifications
You must be signed in to change notification settings - Fork 604
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Generalize the RotatingLogger; size, time or first of the two trigger the rollover #1365
base: main
Are you sure you want to change the base?
Conversation
- Adds a deprecation warning to the TimedRotatingLogger. The TimedRotatingLogger now inherits from the generalized RotatingLogger.
The
Here, a rollover would occur every 5 seconds, or when the buffer and file size becomes 200000. Note that the default Another option would be:
A rollover would occur every 5 seconds, or when the file size becomes 100000 bytes. |
This is inherent to the implementation of logger. When a message is received then the logger is called. The file cannot rollover without there being a message passed to logger. Lines 246 to 251 in 88fc8e5
|
Codecov Report
Additional details and impacted files@@ Coverage Diff @@
## develop #1365 +/- ##
===========================================
+ Coverage 65.16% 65.29% +0.12%
===========================================
Files 81 81
Lines 8853 8779 -74
===========================================
- Hits 5769 5732 -37
+ Misses 3084 3047 -37 |
@zariiii9003 This |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Regarding the discussion in #1364: I generally think that separating what can be split is a fair goal. In this case, however, I think having one class for this makes a lot of sense since it does simplify both user code and the implementation (I think having cooperating sub-classes to have a logger that supports both variants of rotations will not be easier to understand than this).
There are also a few nice small improvements in here that should be merged regardless of the new features!
We should finish the talk about the general API in #1364 before merging here.
Co-authored-by: Felix Divo <[email protected]>
Here is what was stated in the warning message in the `docs` workflow: Warning, treated as error: /home/runner/work/python-can/python-can/can/io/logger.py:docstring of can.io.logger.RotatingLogger:6:py:attr reference target not found: namer Error: Process completed with exit code 2.
Here's what the error check said: Run mypy --python-version 3.7 . can/io/logger.py:487: error: "__init__" of "RotatingLogger" gets multiple values for keyword argument "max_bytes" [misc] Found 1 error in 1 file (checked 55 source files) Error: Process completed with exit code 1.
…c-cook/python-can into issue1364_TimedRotatingLogger
A
RotatingLogger
object is created that constrains the file by file size, time or both. In the case of when both are constrained, the first that occurs will trigger the rollover.RotatingLogger
, don't rollover if there have been no messages received since the last rolloverRotatingLogger
closes #1364