Pixelpulse2 v1.0.5
- Fix unplug (in multi device session) deadlock bug.
- Fix the scanning process for USB devices, to avoid interfering with the signals.
- Add data logger.
- Add device identification using led functionality.
Pixelpulse2 v1.0.4
- Install the updated Windows driver.
Pixelpulse2 v1.0.3
- Fix the export functionality.
Pixelpulse2 v1.0.2
- Fix the update firmware functionality and don't display the update firmware button until the firmware is downloaded.
Pixelpulse2 v1.0.1
- Fixes:
- Make sure the right drivers are used by the Windows installer.
Pixelpulse2 v1.0
- Changed to work with the new rework version of libsmu
- Enhancements
- Open device manager when a device in programming mode is found
- Direct input for Upper and Lower Display Limit
- Trayer Enhancements:
- Show a title when mouse is over the tray icon
- Add a new option to disable / enable Pixelpulse2 autolunch
Pixelpulse2 v0.90
- Enhancements
- Add waveform measurements when in Voltage Measure mode:
- Peak-to-peak Amplitude
- Root mean square
- Lower the minimum required Qt version from 5.4 to 5.3
- Create an out-of-bounds display area on top and bottom of the plot.
- Add the Delayed Acquisition feature
- Display only the voltage plots when in Voltage Measure mode
- Add waveform measurements when in Voltage Measure mode:
- Fixes:
- Small bug fixes for:
- GUI
- session save/restore
- firmware update
- Small bug fixes for:
Pixelpulse2 v0.89
- The updated Libsmu introduces the following:
- Calibration support
- Stability bug fixes
- Version info embedded into the library
- Fix issues with the generation of stair-step and saw-tooth waveforms
- Enhancements
- Display frequency without scientific notation.
- Improve usability of the measurement labels (Voltage, Current, Frequency):
- Select label value by double-clicking (fractional part) and by triple-clicking (both integer and fractional part).
- Limit label value if user sets an out of range value.
- Up/down arrows and pageUp/pageDown keys can be used to quickly change values when focus is on the label.
- Changing the value of the label (Volts or Amperes) will also set the associated channel to source voltage or current.
- Include Pixelpulse2 Trayer in the installer
- Add Plot brightness and contrast control feature
- Add Plot Dot brightness and size control feature
- Add volts/amps labels to the axis of the X-Y plots
- Fixes:
- Fix bug that did not allow user to set the value of a measurement label.
- Fix bug that in certain situations (firmware file could not be accessed) was leaving the M1K device in a programming state.
- Fix bug that did not display the entire buffer of data when switching from a lower 'Sample Time' to higher values.
- Fix bug that made the measurement labels overlap with the right sided panels.
- Show default option for sample time
- Limit the frequency of generated waveforms to 20kHz
- Fix compilation errors if Qt5.5 or higher is used
- Fix bug that was causing a crash when zooming in on the horizontal axis and then changing the sample time to a lower value
- Fix issues with the save/restore session feature
Pixelpulse2 v0.88
Supports measurement and source data calibration
Pixelpulse2 v0.87
pixelpulse2-v0.87_win_setup