You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The PWMi Duty Cycle output = (DCRi)/(CTR+1)
If the DCRi value > CTR value, PWMi signal is still low.
If DCRi value = CTR value, PWMi signal is still high.
Use Cycle Time Register to determine the PWM value that should be used for DCRi.
The problem right now is that PWM_DUTY is used in the fan tables (__code), so it must be a fixed value (which obviously means it can't read from the register).
At the very least, a comment should be added that the 0xFF is the fixed value for CTR0, and that any change to CTR in pwm_init() must be updated here.
Use Cycle Time Register to determine the PWM value that should be used for
DCRi
.255 (0xFF) here should be
CTR0
.The text was updated successfully, but these errors were encountered: