Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

HmIP-BSL 2.0.2 & Signal Node: Color Behaviour missing #177

Open
TinkyWonky opened this issue Jun 24, 2024 · 3 comments
Open

HmIP-BSL 2.0.2 & Signal Node: Color Behaviour missing #177

TinkyWonky opened this issue Jun 24, 2024 · 3 comments

Comments

@TinkyWonky
Copy link

TinkyWonky commented Jun 24, 2024

Using the Signal node to turn on an LED does no longer it turn.

Sample flow export

[
    {
        "id": "31d7f76a8222d74d",
        "type": "inject",
        "z": "acac681abde14c62",
        "name": "true",
        "props": [
            {
                "p": "payload"
            }
        ],
        "repeat": "",
        "crontab": "",
        "once": false,
        "onceDelay": 0.1,
        "topic": "",
        "payload": "true",
        "payloadType": "bool",
        "x": 1490,
        "y": 640,
        "wires": [
            [
                "cbba72f66ab52c73"
            ]
        ]
    },
    {
        "id": "cbba72f66ab52c73",
        "type": "ccu-signal",
        "z": "acac681abde14c62",
        "name": "EG Status Außenverbraucher:12",
        "iface": "HmIP-RF",
        "channel": "001A5A4998C688:12",
        "chime": "",
        "length": 108000,
        "repeat": 1,
        "repeatType": "num",
        "volume": 100,
        "volumeType": "num",
        "line1": "",
        "line2": "",
        "line3": "",
        "signal": "",
        "channelType": "BSL_DIMMER_VIRTUAL_RECEIVER",
        "led": "",
        "acousticAlarmSelection": "DISABLE_ACOUSTIC_SIGNAL",
        "durationUnit": "H",
        "durationValue": "512",
        "durationValueType": "num",
        "rampTimeUnit": "S",
        "rampTimeValue": "1",
        "rampTimeValueType": "num",
        "repetitions": 0,
        "dimmerColor": "4",
        "dimmerLevel": "50",
        "dimmerList": [],
        "soundLevel": 50,
        "soundLevelType": "num",
        "soundList": [],
        "opticalAlarmSelection": "DISABLE_OPTICAL_SIGNAL",
        "ccuConfig": "6d082edf457e16b6",
        "x": 1790,
        "y": 680,
        "wires": []
    },
    {
        "id": "6d082edf457e16b6",
        "type": "ccu-connection",
        "name": "Raspberrymatic",
        ...
    }
]

Firmware 2.0.2 introduced a new datapoint "COLOR_BEHAVIOUR", see HomeMatic Forum Thread. dom.GetObject("HmIP-RF.xxxxxxxxxxxxxx:8.COMBINED_PARAMETER").State (if used) shall now contain ,CB=x with x in

0=OFF, 1=ON,
2=BLINKING_SLOW, 3=BLINKING_MIDDLE, 4=BLINKING_FAST,
5=FLASH_SLOW, 6=FLASH_MIDDLE, 7=FLASH_FAST,
8=BILLOW_SLOW, 9=BILLOW_MIDDLE, 10=BILLOW_FAST,
11?=OLD_VALUE, 12?=DO_NOT_CARE

Apparently, the node does not include this parameter and the device understands it as "0/OFF". Even if the behaviour is manually set to !=0, the node's command makes the device switch the LED off.

Switching manually to "1/ON", the device sends a message indicating that the default parameter is indeed "off":

{
"topic":"172.22.1.1/HmIP-RF/EG Status Außenverbraucher:12/COLOR_BEHAVIOUR",
"payload":1,
"ccu":"172.22.1.1",
"iface":"HmIP-RF",
"device":"001A5A4998C688",
"deviceName":"EG Status Außenverbraucher",
"deviceType":"HmIP-BSL",
"channel":"001A5A4998C688:12",
"channelName":"EG Status Außenverbraucher:12",
"channelType":"DIMMER_VIRTUAL_RECEIVER",
"channelIndex":12,
"datapoint":"COLOR_BEHAVIOUR",
"datapointName":"HmIP-RF.001A5A4998C688:12.COLOR_BEHAVIOUR",
"datapointType":"ENUM",
"datapointMin":"OFF",
"datapointMax":"DO_NOT_CARE",
"datapointDefault":"OFF",
"datapointControl":"DIMMER.COLOR_BEHAVIOUR",
"value":1,
"valuePrevious":1,
"valueStable":1,
"rooms":[],
"functions":   [],
"ts":1719253061541,
"tsPrevious":1719253061465,
"lc":1719253061465,
"change":false,
"cache":false,
"uncertain":false,
"stable":true,
"_msgid":"774c9bccb70739bb"
}

@andesse
Copy link

andesse commented Jun 24, 2024

Use a combined Parameter in the Node. The picture shows a combined Parameter in change nodes I am using for red. Use it as a reference. To turn it off use the Color Parameter in a seperate Node and Set it to 0.

Does this help with your Problem?

Ps: You can test his a combined Parameter should Look Like in the ccu - new program. Use there also combined Parameter and you get a menue. After you Set it up, it is displayed as Text.

image

@TinkyWonky
Copy link
Author

This absolutely helps and is a useful workaround!

Workaround flow

[
    {
        "id": "a3691aa6866b7f2e",
        "type": "change",
        "z": "acac681abde14c62",
        "name": "",
        "rules": [
            {
                "t": "set",
                "p": "payload",
                "pt": "msg",
                "to": "L=50,C=4,DV=31,DU=2,CB=1",
                "tot": "str"
            }
        ],
        "action": "",
        "property": "",
        "from": "",
        "to": "",
        "reg": false,
        "x": 1670,
        "y": 1200,
        "wires": [
            [
                "286bb1510ce00afb"
            ]
        ]
    },
    {
        "id": "f32ea73a5915628b",
        "type": "inject",
        "z": "acac681abde14c62",
        "name": "",
        "props": [],
        "repeat": "",
        "crontab": "",
        "once": false,
        "onceDelay": 0.1,
        "topic": "",
        "x": 1510,
        "y": 1200,
        "wires": [
            [
                "a3691aa6866b7f2e"
            ]
        ]
    },
    {
        "id": "286bb1510ce00afb",
        "type": "ccu-value",
        "z": "acac681abde14c62",
        "name": "",
        "iface": "HmIP-RF",
        "channel": "001A5A4998C688:12 EG Status Außenverbraucher:12",
        "datapoint": "COMBINED_PARAMETER",
        "mode": "",
        "start": true,
        "change": true,
        "cache": false,
        "queue": false,
        "on": 0,
        "onType": "undefined",
        "ramp": 0,
        "rampType": "undefined",
        "working": false,
        "ccuConfig": "6d082edf457e16b6",
        "topic": "${CCU}/${Interface}/${channel}/${datapoint}",
        "x": 1910,
        "y": 1200,
        "wires": [
            []
        ]
    },
    {
        "id": "6d082edf457e16b6",
        "type": "ccu-connection",
        "name": "Raspberrymatic",
        "host": "172.22.1.1",
        "regaEnabled": true,
        "bcrfEnabled": true,
        "iprfEnabled": true,
        "virtEnabled": true,
        "bcwiEnabled": false,
        "cuxdEnabled": true,
        "regaPoll": true,
        "regaInterval": "30",
        "rpcPingTimeout": "60",
        "rpcInitAddress": "",
        "rpcServerHost": "172.22.2.41",
        "rpcBinPort": "2048",
        "rpcXmlPort": "2049",
        "tls": false,
        "inSecure": false,
        "authentication": false,
        "username": "",
        "password": "",
        "queueTimeout": "5000",
        "queuePause": "250",
        "contextStore": "memory"
    }
]

On the other hand, it would be great to achieve this with the dedicated Signal node. ;-)

@andesse
Copy link

andesse commented Jun 24, 2024

Try it out, maybe it works.

I did it this way because I also use different brightness Levels at specific day-times and set it with the LEVEL parameter.

So deactivating the color worked for me best cause the brightness can stay at the same level.

But great that it works:)