added DC personalities for some meters to affected files #308

Open
wants to merge 11 commits into
base: master
Choose a base branch
from
3 changes: 3 additions & 0 deletions compliance/check.py
Original file line number Diff line number Diff line change
Expand Up @@ -49,6 +49,9 @@ class CheckerWarning(Exception):
"YokogawaWT330": 52,
"YokogawaWT330E": 52,
"YokogawaWT330_multichannel": 77,
"YokogawaWT210_DC": 508,
"YokogawaWT310_DC": 549,
"YokogawaWT330_DC": 586,
}

RANGING_MODE = "ranging"
Expand Down
84 changes: 72 additions & 12 deletions ptd_client_server/lib/server.py
Original file line number Diff line number Diff line change
Expand Up @@ -39,6 +39,9 @@
from ptd_client_server.lib import summary as summarylib
from ptd_client_server.lib import time_sync

PTD_READ_ALL_COMMAND_AC_MULTICH = "RL,*,*"
PTD_READ_ALL_COMMAND_AC = "RL"
PTD_READ_ALL_COMMAND_DC = "DC-RL"

RE_PTD_LOG = re.compile(
r"""^
Expand All @@ -63,6 +66,8 @@
# https://github.com/mlcommons/power-dev/issues/220#issue-835336923
DEVICE_TYPE_WT500 = 48

DC_DEVICES = [508, 549, 586]

MAX_RANGE_FOR_DEVICE = {
8: 20, # WT210
49: 20, # WT310
Expand All @@ -72,6 +77,9 @@
48: 40, # WT500_multichannel
47: 50, # WT1800
66: 30, # WT5000
508: 20, # WT210 DC
549: 20, # WT310 DC
586: 20, # WT330 DC
}


Expand Down Expand Up @@ -296,11 +304,15 @@ def get(
"ptd", "channel", parse=parse_channel, fallback=None
)
self.ptd_device_type: int = get("ptd", "deviceType", parse=int)
ptd_dc_flag: Optional[str] = None
if self.ptd_device_type in DC_DEVICES:
ptd_dc_flag = str("-D")
ptd_interface_flag: str = get("ptd", "interfaceFlag")
ptd_device_port: str = get("ptd", "devicePort")
ptd_board_num: Optional[int] = get("ptd", "gpibBoard", parse=int, fallback=None)
# TODO: validate ptd_interface_flag?
# TODO: validate ptd_device_type?
# we can have a list of supported/tested devices and throw a warning when new device is used?
self.ptd_logfile: str = os.path.join(self.tmp_dir.name, "ptd_logfile.txt")
self.ptd_port: int = get("ptd", "networkPort", parse=int, fallback="8888")
self.ptd_command: List[str] = [
Expand All @@ -315,6 +327,7 @@ def get(
if self.ptd_channel is None
else ["-c", ",".join(str(x) for x in self.ptd_channel)]
),
*([] if ptd_dc_flag is None else [ptd_dc_flag]),
*([] if ptd_interface_flag == "" else [ptd_interface_flag]),
str(self.ptd_device_type),
ptd_device_port,
Expand Down Expand Up @@ -464,11 +477,24 @@ def _start(self) -> None:

def grab_power_data(self) -> Tuple[int, str, Optional[str], Optional[str]]:
# (DM) Created method that will utilize SPEC's (only) preferred way of PTD usage and data gathering
power_data_header = self.cmd("RL") # RL - command to show unread samples
power_data_header = self.cmd(
PTD_READ_ALL_COMMAND_AC_MULTICH
) # RL,*,* - command to show unread samples from sum channel and all channels individually
if power_data_header is not None:
number_of_samples = int(
power_data_header.split(" ")[1]
) # first line of response will have message: "Last XYZ samples"
if re.search("Invalid number of parameters", power_data_header):
power_data_header = self.cmd(
PTD_READ_ALL_COMMAND_AC
) # RL - command to show unread samples in case of singlechannel AC
elif power_data_header is not None and re.search(
"Unknown command", power_data_header
):
power_data_header = self.cmd(
PTD_READ_ALL_COMMAND_DC
) # DC-RL - command to show unread samples in case of DC meter
if power_data_header is not None:
number_of_samples = int(
power_data_header.split(" ")[1]
) # first line of response will have message: "Last XYZ samples".
else:
number_of_samples = 0
grabbed_power_data = self.read(number_of_samples)
Expand Down Expand Up @@ -931,10 +957,28 @@ def stop(self, mode: Mode) -> bool:
self._state = SessionState.RANGING_DONE
self._ptd.stop()
samples, log_data, uncertainty_data, sanity = self._ptd.grab_power_data()
# (DM) TODO: figure out how to flag/report number of unvertain samples and how to disqualify bad run(s)
formatted_log_data = log_data.replace(
"\n", str(",Mark," + self._id + "_ranging\n")
) # honoring format of legacy spl.txt
# (DM) really ugly function that will parse telnet log and reformat it in log that is same as ptd.log
# If anyone knows how to do it better, please do
lines = log_data.split("\n")
formatted_log_data = ""
for ii in range(len(lines)):
temp = lines[ii].split("Watts")
line_fixed = ""
for jj in range(len(temp)):
line_fixed += temp[jj]
if jj > 0 and (jj < len(temp) - 1 or len(temp) == 2):
if jj == 1:
if len(temp) == 2:
line_fixed += ","
line_fixed += "Mark," + self._id + "_ranging"
if len(temp) > 2:
line_fixed += ","
if len(temp) > 2:
line_fixed += "Ch" + str(jj) + ","
if jj < len(temp) - 1:
line_fixed += "Watts"
formatted_log_data += line_fixed + "\n"

assert self._go_command_time is not None
test_duration = time.monotonic() - self._go_command_time
dirname = os.path.join(self.log_dir_path, "ranging")
Expand Down Expand Up @@ -996,10 +1040,26 @@ def stop(self, mode: Mode) -> bool:
dirname = os.path.join(self.log_dir_path, "run_1")
os.mkdir(dirname)
samples, log_data, uncertainty_data, sanity = self._ptd.grab_power_data()
# (DM) TODO: figure out how to flag/report number of unvertain samples and how to disqualify bad run(s)
formatted_log_data = log_data.replace(
"\n", str(",Mark," + self._id + "_testing\n")
) # honoring format of legacy spl.txt
# (DM) TODO: figure out how to flag/report number of unvertain samples and how to disqualify bad run(s)lines = log_data.split("\n")
lines = log_data.split("\n")
formatted_log_data = ""
for ii in range(len(lines)):
temp = lines[ii].split("Watts")
line_fixed = ""
for jj in range(len(temp)):
line_fixed += temp[jj]
if jj > 0 and (jj < len(temp) - 1 or len(temp) == 2):
if jj == 1:
if len(temp) == 2:
line_fixed += ","
line_fixed += "Mark," + self._id + "_testing"
if len(temp) > 2:
line_fixed += ","
if len(temp) > 2:
line_fixed += "Ch" + str(jj) + ","
if jj < len(temp) - 1:
line_fixed += "Watts"
formatted_log_data += line_fixed + "\n"
with open(os.path.join(dirname, "spl.txt"), "w") as f:
f.write(formatted_log_data)
with open(os.path.join(dirname, "ptd_out.txt"), "w") as f:
Expand Down
1 change: 1 addition & 0 deletions ptd_client_server/server.template.conf
Original file line number Diff line number Diff line change
Expand Up @@ -57,3 +57,4 @@ devicePort: COM1
# Channel value should consist of two numbers separated by a comma for a multichannel analyzer.
# Channel value should consist of one number or be disabled for a 1-channel analyzer.
#channel: 1,2