Notifications
You must be signed in to change notification settings - Fork 66
Warning about Victron MPPT 100 20
UPDATE: This issue was resolved in MPPT firmware V1.64
More info here - "SmartSolar v1.64 - stability improvements to specific models"
Thanks to everyone who contributed to the identification and reporting of this issue.
Many users with Victron 100/20 reported that strange behaviour Victron 100/20 with variable cloudiness
It seems to be a well-known phenomenon that the Victron 100/20s go down once every 10 minutes and the voltage drops (The behavior every 10 min is normal - that is the MPPT looking for the new maximum power point). If this happens at a moment when the cloud cover is changing rapidly (April weather), the Victron hangs at 3-4W charging power. Often it manages to recover at the next 10min interval. But sometimes it takes much longer... which is really annoying! What leads to success much faster is to deactivate the charger in the APP and activate it again.
The behavior from your lower diagram is not normal - I also have this on my 100/20 and am almost desperate. I have also already contacted Victron support - but there no one really took me seriously and they said that I should buy a Cerbo GX to it (bullshit). My charge controller is also not defective - I have already replaced it and the new one shows exactly the same behavior. I have tried forever around and could not solve the problem directly. Then I made a workaround with Homeassistant: If the PV voltage (in my case) greater than 73V (open circuit voltage) and the MPPT is in "bulk" and produces a power of less than 5W, then I switch a relay that disconnects the PV input from the Victron for 15 sec. and then reconnects - then it immediately continues normally. Too bad that Victron does not take you seriously. I assume that it is a firmware bug - but for 6 months there was no update (have v161 on it). With a friend these problems do not occur with the 150/35.
- Home
- FAQ
- First-Time Installation
- Device Profiles (Pin Config)
- Upgrade from OpenDTU
- Getting Help
- Hilfe erhalten
- Builds & Examples
- ESP32 Versions and Memory
- Victron MPPT solar charger
- VE.Direct
- Victron Smartshunt
- Victron Smart Battery Sense
- Warning on Victron MPPT 100/20
- Pylontech battery
- Pytes battery
- Huawei AC PSU
- SBS Unipower Battery
- Jikong JK BMS
- HOYMILES
- Einschaltstrombegrenzung für Balkonkraftwerke - Inrush current limiter
- Live View
- Farbe des Wechselrichterfensters
- Power Meter
- Dynamic Power Limiter
- Dynamic Power Limiter ‐ (Full) Solar‐Passthrough
- Dynamic Power Limiter Limitations
- DC Voltage ‐ Load correction factor
- Battery
- Battery-Tipps
- 24V Battery issues with Hoymiles
- Home Assistant
- Grafana Dashboard
- XXL Balkonkraftwerk 1500 Watt und mehr! Worauf Ihr achten solltet!
- Wie gefährlich kann ein Balkonkraftwerk werden (FI‐Schutzschalter)
- Hardware Purchase Tipp
- Fan speed controller ‐ add temperature sensing to any fan
- Cable length(s) between battery and inverter
- Kabellänge(n) zwischen Batterie und Wechselrichter
- Diodes ‐ Bypass vs. Blocking Diodes
- Impact of high start-currents to the inverter
- Making Cables for your HOYMILES‐CAUTION