Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Endpoint count limitation still 2? #22

Open
konistehrad opened this issue Nov 14, 2023 · 3 comments
Open

Endpoint count limitation still 2? #22

konistehrad opened this issue Nov 14, 2023 · 3 comments

Comments

@konistehrad
Copy link

I'm currently working on adding Green Power support to zigpy, and unfortunately the "only 2 endpoints" issue has finally bitten us. Given this current limitation, we're currently unable to add support for green power to zigpy-deconz. Any status updates on this issue would be greatly appreciated.

@Hedda
Copy link

Hedda commented Nov 21, 2023

@manup was it not mentioned in #17 and zigbeefordomoticz/Domoticz-Zigbee#1145 that you guys were working on a new deconz firmware for ConBee II and RaspBee II with support for more than two endpoints?

For reference, there are also related discussions here:

#17

zigbeefordomoticz/Domoticz-Zigbee#1145

zigpy/zigpy-deconz#234

zigpy/zigpy-deconz#196

@Hedda
Copy link

Hedda commented Sep 20, 2024

@konistehrad @manup Follow-up question is if this is still a deconz serial protocol limitation for the new ConBee III (ConBee 3)?

Just thinking it should not have this limitation since ConBee III (ConBee 3) is based on EmberZNet Zigbee stack under the hood.

@konistehrad
Copy link
Author

No idea, my current net is working off a CC2652, though I also ran it off an MG21 for a while, indicating it should work as expected barring third party modifications.