Battery Testing Consortium (BTC)

The Battery Testing Consortium (BTC) has been developed within the High Voltage and Energy Storage Lab at Oxford Brookes University to provide accurate and comprehensive cell data to Formula Student Electric teams. Through the BTC, we aim to provide FS teams with information for improved and informed decisions for cell selection, pack architecture design, thermal cooling requirements, and end of life predictions. A range of tests are completed to provide a comprehensive electrochemical lithium-ion characterisation for modelling, validation, and battery management parameterisation.

This repository provides one open-source sample dataset of the larger consortium dataset. To join the consortium, visit the HVES website.

Total Consortium Cells

Cell Chemistry Nom. Voltage [V] Nom. Capacity [Ah] Energy Density [Wh/kg]
Samsung 25R NMC 3.6 2.5 206
LG HG2 NMC 3.6 3 236
Sony VTC6 NMC 3.6 3 232
Melasta SLPB6542126 LCO 3.7 3.9 191
Melasta SLPB8542126 LCO 3.7 5.2 189
Melasta SLPB8346143 LCO 3.7 6.3 196
Melasta SLPBB142124 LCO 3.7 6.8 202
Melasta SLPB8870175 LCO 3.7 12 197
Melasta SLPB7336128HV NMC 3.8 3.7 204
Melasta SLPB9542124HV NMC 3.8 5.95 215
Melasta SLPBB042126HV NMC 3.8 7.5 228
Melasta SLPB7579207HV NMC 3.8 15.4 227

Notes

  • For all tests dated before September 25th, 2021: Offset thermocouple measurements by 1.5°C (i.e. 30°C -> 28.5°C).
  • Unless stated otherwise, all cells are stored in a controlled climate at 15°C.

Consortium Overview

An abriged overview describing the tests completed and data organisation can be found in here.

Contact / Issues

For issues and bugs, please open an issue. All feedback is welcome. To get involved or discuss testing methods, please contact [email protected].