forked from simonjj/SnmpMibs
-
Notifications
You must be signed in to change notification settings - Fork 0
/
CISCO-ASPP-MIB.mib
467 lines (418 loc) · 17.9 KB
/
CISCO-ASPP-MIB.mib
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
-- *****************************************************************
-- CISCO-ASPP-MIB.my: Asynchronous Security Poll Protocols.
--
-- May 1996, Andrew R. Rothwell.
-- October 2002, Michael Belscher
--
-- Copyright (c) 1996-1997, 2003 by cisco Systems, Inc.
-- All rights reserved.
--
-- *****************************************************************
CISCO-ASPP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
ifIndex
FROM IF-MIB
TruthValue
FROM SNMPv2-TC
ciscoMgmt
FROM CISCO-SMI;
ciscoAsppMIB MODULE-IDENTITY
LAST-UPDATED "200302100000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Cisco Systems
Customer Service
Postal: 170 W. Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: [email protected]"
DESCRIPTION
"The ASPP MIB provides the configuration and operational
information on asynchronous polled protocols such as the
asynchronous security protocols that alarm monitoring
companies use. The protocols are handled in passthrough
mode. ASPP will handle the receiving and sending of the
asychronous blocks. It will not perform any error
checking. It is the responsibilty of the end-station to
perform any required error recovery. A generic protocol
has been created to support asychronous protocols. In
some situations this doesn't work for all types since
there is no alarm protocol standard. Specific vendor
support has been included for the following vendor's
alarm equipment and protocols:
* adplex
* adt
- PollSelect
- VariPoll
* diebold
* mdi
* mosec (mosler)
* gddb (Guang Dong Development Bank)
- This protocol is similar to Burroughs Poll/Select
The following example configuration shows how the
ASPP MIB returns ASPP information, from either CISCO A
or CISCO B.
Security == ASP == Cisco == IP == Cisco == ASP == Alarm
control A Network B Panel
station
The following entities are managed:
1) ASPP ports (serial interfaces)
The ASPP ports are identified by the interface index,
and additional information about this interface can be
obtained from the Cisco Serial Interface MIB."
REVISION "200302100000Z"
DESCRIPTION
"Added Asynchronous Point of Sale(POS) to IP conversion
support.
The APOS protocol utilizes asynchrounous communications
with 1 start, 1 stop and 7 data bits with even
parity. The connection to the POS terminal will always
be an asynchronous leased line. The protocol has many
characteristics of BSC except it is simplified to
minimize overhead on the point to point connection.
The added APOS traffic will be locally acknowledged
unlike the other polled asynchronous protocol which
function in passthrough mode.
The LRC/VRC will be verified and any necessary recovery
will be done by the router.
This is necessary since we are converting the protocol
so the data can be passed to an IP attached host."
REVISION "9508210000Z"
DESCRIPTION
"Initial mib for async security polled protocols."
::= { ciscoMgmt 55 }
asppObjects OBJECT IDENTIFIER ::= { ciscoAsppMIB 1}
asppPorts OBJECT IDENTIFIER ::= { asppObjects 1}
-- *********************************************************************
-- * Aspp Port Table
-- *********************************************************************
asppPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AsppPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of asynchronous interfaces which have been
configured to support an asynchronous security protocol
(ASP) BSTUN group."
::= { asppPorts 1 }
asppPortEntry OBJECT-TYPE
SYNTAX AsppPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Current ASP configuration settings for an asynchronous
port."
INDEX { ifIndex }
::= { asppPortTable 1 }
AsppPortEntry ::=
SEQUENCE {
asppPortProtocol INTEGER,
asppPortRole INTEGER,
asppPortReceiveInterFrameTimeout Integer32,
asppPortDeviceAddressOffset Integer32,
asppPortEOFCharacter Integer32,
asppPortSOFCharacter Integer32,
asppPortIgnoreSequenceNumber TruthValue,
asppPortRspTimer Integer32,
asppPortRxTimer Integer32,
asppPortHostTimer Integer32,
asppPortConnectTimer Integer32,
asppPortRetryCount Integer32,
asppPortDelayEnq Integer32,
asppPortDisableEnq TruthValue,
asppPortSendAck TruthValue,
asppPortDirect TruthValue,
asppPortDCDAlways TruthValue
}
asppPortProtocol OBJECT-TYPE
SYNTAX INTEGER {
adplex(1),
adtPollSelect(2),
adtVariPoll(3),
diebold(4),
asyncGeneric(5),
mdi(6),
mosec(7),
gddb(8),
apos(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies type of asynchronous security protocol being
used. These protocols are implemented by individual
security alarm manufacturers. There is no standard
protocol for alarm communications over RS-232
interfaces.
asyncGeneric(5)- provides generic polled asynchronous
support
Specific vendor support has been included for the
following vendor's alarm equipment and protocols:
* adplex(1)
* ADT
- adtPollSelect(2)
- adtVariPoll(3)
* diebold(4)
* mdi(6)
* mosec(7)
- mosler equipment
* gddb(8)
- Guang Dong Development Bank
The protocol is similar to Burroughs
Poll/Select.
apos(9) - Protocol support for asynchronous POS
devices for provide credit and debit card
authorizations to an IP attached host."
::= { asppPortEntry 1 }
asppPortRole OBJECT-TYPE
SYNTAX INTEGER { primary(1), secondary(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the router's protocol role.
primary(1) - Indicates we are attaching to the terminal
or alarm panel.
secondary(2) - Indicates we are attaching to the host
or alarm console.."
::= { asppPortEntry 2 }
asppPortReceiveInterFrameTimeout OBJECT-TYPE
SYNTAX Integer32 (0..1000)
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the receive inter-frame-timeout period, used
to delimit frames. Since all the protocols are
implemented over RS-232 3-wire circuits (ie TX, RX and
GND), the only general method for start-end frame
detection is to monitor the time between received
characters. If this time period exceeds the inter-frame
timeout value, then frame end-start is detected."
::= { asppPortEntry 3 }
asppPortDeviceAddressOffset OBJECT-TYPE
SYNTAX Integer32 (0..255)
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the byte offset within a frame, which
contains the device address. This is used when the
asynchronous interface is configured to use the async
generic protocol handler. Because no knowledge of the
protocol is built-in to the IOS, it must be told where
the address field lives within the frame. That way IOS
can correctly route the frames for this protocol."
REFERENCE
"CISCO-BSTUN-MIB"
::= { asppPortEntry 4 }
asppPortEOFCharacter OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the protocol character to use to delimit
the end of a frame. The valid character is 0-255 and
256 indicates the object is not configured."
::= { asppPortEntry 5 }
asppPortSOFCharacter OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the protocol character to use to delimit
the beginning of a frame. The valid character is 0-255
and 256 indicates the object is not configured."
::= { asppPortEntry 6 }
asppPortIgnoreSequenceNumber OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the asp sequence numbers used to
synchronize aspp traffic between head-end and tail-end
routers should be ignored. This is enabled if there
isn't a one to one correlation between commands and
responses between the two routers."
DEFVAL { false }
::= { asppPortEntry 7 }
asppPortRspTimer OBJECT-TYPE
SYNTAX Integer32 (1..30)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the amount of time the router will wait for a
response to a packet before retransmission."
::= { asppPortEntry 8 }
asppPortRxTimer OBJECT-TYPE
SYNTAX Integer32 (10..60)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum amount of time the router will
wait for a complete packet to be received. It starts
when an STX character is received."
::= { asppPortEntry 9 }
asppPortHostTimer OBJECT-TYPE
SYNTAX Integer32 (10..120)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum amount of time the router will
wait for a response to a terminal request from the
host. It starts when a terminal request is forwarded
to the host."
::= { asppPortEntry 10 }
asppPortConnectTimer OBJECT-TYPE
SYNTAX Integer32 (1..30)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum amount of time the router will
wait for the activation of the tunnel connection to the
host to complete. It starts when a terminal requests a
session with host."
::= { asppPortEntry 11 }
asppPortRetryCount OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the maximum number of timers a packet will be
retransmitted before the connection with the terminal
will be disconnected."
::= { asppPortEntry 12 }
asppPortDelayEnq OBJECT-TYPE
SYNTAX Integer32 (1..1000)
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the amount of time to wait after sending a
connect packet to the the terminal before sending the
ENQ to initiate a session"
::= { asppPortEntry 13 }
asppPortDisableEnq OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether sending of ENQ to initiate a session
with the terminal is disabled."
DEFVAL { false }
::= { asppPortEntry 14 }
asppPortSendAck OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the router will send an ACK to
acknowledge packets."
DEFVAL { false }
::= { asppPortEntry 15 }
asppPortDirect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether the line mode is direct or dialed.
If in direct the router will immediately send ENQ
without waiting for AT commands"
DEFVAL { false }
::= { asppPortEntry 16 }
asppPortDCDAlways OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies whether DCD should always be asserted or
asserted only when the connection is active."
DEFVAL { false }
::= { asppPortEntry 17 }
-- *************************************************************************
-- * Conformance Information
-- *************************************************************************
asppMibConformance OBJECT IDENTIFIER ::= { ciscoAsppMIB 3 }
asppMibCompliances OBJECT IDENTIFIER ::= { asppMibConformance 1 }
asppMibGroups OBJECT IDENTIFIER ::= { asppMibConformance 2 }
--
-- *************************************************************************
-- * Compliance Statements
-- *************************************************************************
asppMibCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for ASP."
MODULE -- this module
MANDATORY-GROUPS {
asppPortsGroup
}
::= { asppMibCompliances 1 }
asppMibComplianceRev1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for ASP."
MODULE -- this module
MANDATORY-GROUPS {
asppPortsGroup
}
GROUP asppPortsGenericGroup
DESCRIPTION
"This group is mandatory when implementing
asyncGeneric protocol."
GROUP asppPortsAposGroup
DESCRIPTION
"This group is mandatory when implementing
the apos protocol."
::= { asppMibCompliances 2 }
asppPortsGroup OBJECT-GROUP
OBJECTS {
asppPortProtocol,
asppPortRole,
asppPortReceiveInterFrameTimeout,
asppPortDeviceAddressOffset
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
interfaces that run asynchronous security protocols."
::= { asppMibGroups 1}
asppPortsGenericGroup OBJECT-GROUP
OBJECTS {
asppPortEOFCharacter,
asppPortSOFCharacter,
asppPortIgnoreSequenceNumber
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
interfaces that run asynchronous generic protocols."
::= { asppMibGroups 2}
asppPortsAposGroup OBJECT-GROUP
OBJECTS {
asppPortRspTimer,
asppPortRxTimer,
asppPortHostTimer,
asppPortConnectTimer,
asppPortRetryCount,
asppPortDelayEnq,
asppPortDisableEnq,
asppPortSendAck,
asppPortDirect,
asppPortDCDAlways
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
interfaces that run asynchronous protocol to communicate
to Point of Sale protocols."
::= { asppMibGroups 3}
END